  1. Haze UPS & Telecom Batteries HZS12-8

    Learn More
    Valve Regulated Lead Acid Battery for communications standby power & UPS applications Innovative Features • Completely maintenance free,sealed construction eliminates the need for watering • Increased durability and deep cycle ability for heavy demand applications • Fully tank formed plates • Low impurity electrolyte • Spill proof / leak proof • Valve regulated Max internal pressure 2.5 psi • Multi-position usage • ABS Case and cover - V0 on request • Low self discharge • FAA and IATA approved as nonhazardous. Specifications • Nominal Voltage - 12 Volts • Nominal Capacity 8 Ah (C20 @ 20 C) • Design Life - 5 Years • Operating Temperature -20 °C to 50 °C (Recommended) • Grid alloy - Calcium / Tin lead alloy • Plates- Flat Pasted • Separator - Absorbant Glass Mat • Active material - High purity lead • Case and cover - ABS (VO on request) • Charge Voltage - Float 2.27 - 2.30 VPC @20 °C Cycliing 2.4 @20 °C Max. 2.4 VPC Max ripple 0.05C (A) • Electrolyte - Sulphuric acid Low impurity • Venting Valve - EPDM Rubber 1.5 to 2 psi (10.5 - 14 KPa) release pressure. Resealing at 1 psi (7 KPa) • Terminal - T2 - 0.250” Fast-On Tab terminal Learn More

  2. Haze UPS & Telecom Batteries HZS12-9

    Learn More
    Valve Regulated Lead Acid Battery for communications standby power & UPS applications. These Sealed Lead Acid Monobloc Batteries are manufactured using only the finest materials and have been superbly designed so they are completely maintenance free, while the sealed construction eliminates the need for watering. Innovative Features • Completely maintenance free,sealed construction eliminates the need for watering • Increased durability and deep cycle ability for heavy demand applications • Fully tank formed plates • Low impurity electrolyte • Spill proof / leak proof • Valve regulated Max internal pressure 2.5 psi • Multi-position usage • ABS Case and cover - V0 on request • Low self discharge • FAA and IATA approved as nonhazardous. Specifications • Nominal Voltage - 12 Volts • Nominal Capacity 8 Ah (C20 @ 20 C) • Design Life - 5 Years • Operating Temperature -20 °C to 50 °C (Recommended) • Grid alloy - Calcium / Tin lead alloy • Plates- Flat Pasted • Separator - Absorbant Glass Mat • Active material - High purity lead • Case and cover - ABS (VO on request) • Charge Voltage - Float 2.27 - 2.30 VPC @20 °C Cycliing 2.4 @20 °C Max. 2.4 VPC Max ripple 0.05C (A) • Electrolyte - Sulphuric acid Low impurity • Venting Valve - EPDM Rubber 1.5 to 2 psi (10.5 - 14 KPa) release pressure. Resealing at 1 psi (7 KPa) • Terminal - T2 - 0.250” Fast-On Tab terminal Learn More

Grid  List 

Set Descending Direction
per page