MidNite’s breakers are rated to break the full rated load at the rated voltage repeatedly, with no damage. Always use a properly sized breaker for disconnecting.Photovoltaic (PV) Array Breakers PV breakers are Hydraulic-Magnetic type and are not affected by high ambient temperatures. All breakers have a 2 year warranty. These breakers can accept wire sized AWG #6 through AWG#14. They will fit in enclosures with din rails.

- Environmental Rating - Type 1 (Indoor)
- DC Voltage Rating - 150VDC
- Wire Size Range - 14 to 6 AWG
- Width - .51 in (13mm)
- Number of poles - 1
- 10,000 AIC

MNEPV breakers are the same as CBI QY breakers except the standard used is inadequate for the solar industry. MidNite breakers have been evaluated by ETL to 150VDC and are listed for US and Canada. All of the NRTL listings still apply. Breakers ordered under the CBI part numbering system will not be listed for 150VDC and in many cases are not suitable for the solar industry. All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. Breaker Torque Value: 20 In-Lbs (2.3NM)
$12.00

product pro


Additional Information

Part Number MNEPV
Capacity 150VDC
Length 2.9 in.
Width 4.7 in
Height 5 in.
Weight 25 lbs.
Brand MidNite Solar
Midnite Solar MNEPV Din Rail Breakers

Midnite Solar MNEPV Din Rail Breakers . MidNite’s breakers are rated to break the full rated load at the rated voltage repeatedly, with no damage. Always use a properly sized breaker for disconnecting.Photovoltaic (PV) Array Breakers PV breakers are Hydraulic-Magnetic type and are not affected by high ambient temperatures. All breakers have a 2 year warranty. These breakers can accept wire sized AWG #6 through AWG#14. They will fit in enclosures with din rails. - Environmental Rating - Type 1 (Indoor) - DC Voltage Rating - 150VDC - Wire Size Range - 14 to 6 AWG - Width - .51 in (13mm) - Number of poles - 1 - 10,000 AIC MNEPV breakers are the same as CBI QY breakers except the standard used is inadequate for the solar industry. MidNite breakers have been evaluated by ETL to 150VDC and are listed for US and Canada. All of the NRTL listings still apply. Breakers ordered under the CBI part numbering system will not be listed for 150VDC and in many cases are not suitable for the solar industry. All MidNite circuit breakers can be used at 100% rated current when mounted in a MidNite enclosure. Breaker Torque Value: 20 In-Lbs (2.3NM)